內窺鏡設備維修的流程和手段

來源:http://www.csfqw.net/ 發布時間:2025-03-20 瀏覽量:0

在現代醫療體系中,內窺鏡設備作為診斷與治療諸多疾病的 “神兵利器”,其重要性不言而喻。無論是胃鏡深入胃部探尋病變,還是腹腔鏡在腹腔內輔助精準手術,內窺鏡都憑借獨特的可視化功能,為醫療工作者提供關鍵的診斷依據,極大提升了醫療服務的精準性與有效性。然而,這類精密儀器在高頻使用過程中,極易出現各類故障,此時,專業的內窺鏡設備維修便成為保障醫療流程順暢、維系患者健康的重要環節。
In the modern medical system, the importance of endoscopic equipment as a "divine weapon" for diagnosing and treating many diseases is self-evident. Whether it is gastroscopy exploring lesions in the stomach or laparoscopy assisting precise surgery in the abdominal cavity, endoscopes provide key diagnostic basis for medical workers with their unique visualization function, greatly improving the accuracy and effectiveness of medical services. However, such precision instruments are prone to various malfunctions during high-frequency use, and professional maintenance of endoscopic equipment becomes an important link in ensuring smooth medical processes and maintaining patient health.
維修流程與技術手段?
Maintenance process and technical means
故障檢測與診斷?
Fault detection and diagnosis
維修人員接到故障內窺鏡后,首先會進行全面的外觀檢查,查看是否有明顯的物理損傷,如外殼破裂、線纜破損等。接著,使用專業的檢測設備對內窺鏡的光學、電子、機械系統進行詳細測試。對于光學系統,通過光學檢測儀器評估圖像質量、物鏡焦距、導光束亮度等參數;針對電子系統,利用示波器、信號發生器等設備檢測信號傳輸情況,判斷電子元件是否正常工作;在機械結構方面,通過手動操作彎曲部、活檢鉗道等,檢查其運動是否順暢,有無卡頓、異常阻力等現象。結合檢測數據與實際觀察,準確判斷故障類型與具體位置。?
After receiving the faulty endoscope, the maintenance personnel will first conduct a comprehensive visual inspection to check for any obvious physical damage, such as shell rupture, cable damage, etc. Next, use professional testing equipment to conduct detailed tests on the optical, electronic, and mechanical systems of the endoscope. For optical systems, parameters such as image quality, objective lens focal length, and guide beam brightness are evaluated using optical detection instruments; For electronic systems, use equipment such as oscilloscopes and signal generators to detect signal transmission and determine whether electronic components are working properly; In terms of mechanical structure, manually operate the bending part, biopsy forceps, etc. to check whether their movement is smooth, whether there are any jamming, abnormal resistance, and other phenomena. By combining detection data with actual observation, accurately determine the type and specific location of the fault. ?
維修與更換零部件?
Repair and replacement of parts
根據故障診斷結果,維修人員采取相應的維修措施。對于光學系統故障,若物鏡磨損較輕,可通過專業的研磨、拋光工藝進行修復;鏡片污染則需使用專用的清潔劑進行精細清洗;若導光束斷裂,需精確更換受損的導光纖維。電子系統故障維修時,對于損壞的圖像傳感器、集成電路等元件,需在防靜電環境下進行精準焊接更換;修復信號傳輸線路時,要仔細排查斷路、短路點,進行焊接或線纜更換。機械結構故障處理中,彎曲部鋼絲斷裂需更換全新鋼絲,并重新調試彎曲角度;角度控制裝置的磨損部件要進行更換或修復,確保角度控制的準確性;活檢鉗道堵塞則采用專用的疏通工具和清洗液進行清理。?
According to the fault diagnosis results, maintenance personnel take corresponding maintenance measures. For optical system failures, if the objective lens wears lightly, it can be repaired through professional grinding and polishing processes; Lens contamination requires the use of specialized cleaning agents for fine cleaning; If the light guide beam breaks, the damaged light guide fiber needs to be replaced accurately. When repairing electronic system malfunctions, damaged components such as image sensors and integrated circuits need to be precisely welded and replaced in an anti-static environment; When repairing signal transmission lines, it is necessary to carefully investigate open circuits and short-circuit points, and perform welding or cable replacement. In the handling of mechanical structural faults, if the steel wire in the bending part breaks, it needs to be replaced with a new steel wire and the bending angle needs to be readjusted; The worn parts of the angle control device need to be replaced or repaired to ensure the accuracy of angle control; If the biopsy forceps are blocked, specialized dredging tools and cleaning solution are used for cleaning. ?
03
校準與測試?
Calibration and Testing
維修完成后,為確保內窺鏡設備恢復到最佳性能狀態,需進行嚴格的校準與測試。光學系統校準包括圖像清晰度、色彩還原度、亮度均勻性等參數的調整;電子系統校準要對圖像信號的增益、偏置等進行優化,保證圖像質量穩定;機械結構校準則著重調整彎曲部的彎曲角度范圍、活檢鉗道的開合力度等。在校準完成后,還需進行模擬臨床使用的全面測試,包括將內窺鏡插入模擬人體模型,檢查圖像質量、角度控制、活檢鉗道功能等是否正常,只有通過測試的設備才能重新投入臨床使用。
After the repair is completed, strict calibration and testing are required to ensure that the endoscope equipment is restored to its optimal performance state. Optical system calibration includes adjusting parameters such as image clarity, color reproduction, and brightness uniformity; Electronic system calibration should optimize the gain and bias of image signals to ensure stable image quality; The mechanical structure calibration criteria focus on adjusting the bending angle range of the bending part and the opening and closing force of the biopsy forceps channel. After calibration is completed, comprehensive testing is required to simulate clinical use, including inserting an endoscope into a simulated human body model to check image quality, angle control, biopsy forceps function, etc. Only devices that pass the testing can be put back into clinical use.
本文由內窺鏡設備維修向大家友情奉獻.更多有關的知識請點擊:http://www.csfqw.net我們將傾情為您解答.
This article is a friendly contribution from the maintenance of endoscopic equipment to everyone For more related knowledge, please click: We will wholeheartedly answer your questions
s
新聞資訊
聯系我們
  • 公司公司:匠仁醫療設備有限公司
  • 匠仁醫療山東濟南維修部
  • 聯系人:樊經理
  • 電話:13153199508
  • 地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室
  • 匠仁醫療湖南長沙維修部
  • 聯系人:李經理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室
新聞資訊

樊經理:13153199508     李經理:13873135765

公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室  湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室

     

魯公網安備 37010402441281號